Respiratory Virus PCR (View in report form.)

CERNER / EPIC MNEMONIC:

RESVIRPCR

CPT CODE:

83900, 83901 x 6

TEST INFORMATION:

This test is used to detect the presence of RNA from Influenza A, Influenza B, Respiratory Syncytial Virus, Parainfluenza viruses 1, 2, 3 and 4, Adenovirus, Entero/Rhino Virus and Human Metapneumo Virus.

DAYS PERFORMED:

Monday through Saturday during  respiratory virus infection season

TURNAROUND TIME:

24- 48 hours

SPECIAL INSTRUCTIONS:

Specimen must be received by the Clinical Microbiology Laboratory no later than 6:00am on the day of testing for same day result.

CONTAINER TYPE:

Nasopharyngeal swabs and throat swabs should be placed in M4 viral transport media.  Nasopharyngeal aspirates, nasopharyngeal washes, or bronchoalveolar lavage should be placed in a sterile container.

SPECIMEN REQUIREMENTS:

Nasopharyngeal swab, nasopharyngeal aspirate, nasopharyngeal washes

REJECTION CRITERIA:

Inappropriate specimen, improper collection, inappropriate specimen container, improper storage, unlabeled specimen, mislabeled specimen.

MINIMUM VOLUME:

1 ml

HANDLING INSTRUCTIONS:

Specimens should be transported to the laboratory as soon as possible.  When transportation is delayed, refrigerate the specimen

REFERENCE RANGE:

This assay will be reported as 'RNA detected', 'No RNA detected' for each viral target.

LIMITATIONS OF TEST:

A negative result does not exlude the possibility of respiratory virus infection since very low levels of infection or sampling error may cause a false negative result.  The assay does not detect respiratory viruses other than those listed above.

METHODOLOGY:

Polymerase Chain Reaction with detection by Luminex technology

LAST UPDATED:

6-3-2014


Click here to go back to the alphabetic listing.



Tube Guide - Order of Draw
Lab Manual Index
About RML
Search
Testing Services
User Guide
Production Schedule
General Laboratory Information
Normal Ranges for Common Laboratory Tests
Critical Values
Neonatal Screening
Licensing Information
Departments
Staff Directory
Contact Us
    Find a Doctor | Patient & Visitor Services | Health Information
Clinical Services | Events & Classes | Rush News Room | Clinical Trials
Research At Rush | Nursing At Rush | Work At Rush
Disclaimer | Privacy Statement | Site Map

FOR RUSH EMPLOYEES

© Rush University Medical Center, Chicago, Illinois